These results have been submitted to SPEC; see the
disclaimer before studying any results.
Last update: Thursday, 24 July 2014, 11:40
SPECsfs2008 results may only be compared to other SPECsfs2008 results for the same protocol. SPECsfs2008_cifs and SPECsfs2008_nfs.v3 are not comparable because they are generated using completely different workloads.
Tested By | Product Name | Results | System Configuration | ||||||
---|---|---|---|---|---|---|---|---|---|
Throughput | ORT | Protocol | Memory (GB) |
Disks | Exported Capacity |
Network Ports |
Network Type |
||
Apple Inc. | 3.0 GHz 8-Core Xserve HTML | Text |
13092 | 1.19 | CIFS | 20 | 49 | 13.4 TB | 4 | Gigabit Ethernet |
Apple Inc. | Xserve (Early 2009) with Snow Leopard Server HTML | Text |
44347 | 1.89 | CIFS | 56 | 65 | 9.1 TB | 8 | Gigabit Ethernet |
Apple Inc. | Xserve (Early 2009) with Leopard Server HTML | Text |
19313 | 1.89 | CIFS | 56 | 65 | 9.1 TB | 3 | Gigabit Ethernet |
EMC Corporation | Celerra Gateway NS-G8 Server Failover Cluster, 3 Datamovers (1 stdby) / Symmetrix V-Max HTML | Text |
118463 | 1.92 | CIFS | 264 | 100 | 17600 GB | 8 | Jumbo Gigabit Ethernet |
EMC Corporation | Celerra VG8 Server Failover Cluster, 2 Data Movers (1 stdby) / Symmetrix VMAX HTML | Text |
142979 | 1.92 | CIFS | 280 | 312 | 44384 GB | 8 | Jumbo Gigabit Ethernet |
EMC Corporation | EMC VNX VG8 Gateway/EMC VNX5700, 5 X-Blades (including 1 stdby) HTML | Text |
661951 | 0.81 | CIFS | 240 | 581 | 77455 GiB | 8 | Jumbo 10GbE |
EMC Isilon | S210-2U-Dual-256GB-2x1GE-2x10GE SFP+-14TB-800GB SSD - 14 Nodes HTML | Text |
364149 | 1.11 | CIFS | 3612 | 336 | 145TB | 14 | Single 10GbE interface configured on each node, 1500 MTU |
Fujitsu | PRIMERGY TX300 S5 (with 3x6 disks RAID 0) HTML | Text |
16488 | 4.68 | CIFS | 97 | 20 | 2.4 TB | 2 | Gigabit Ethernet |
Fujitsu | PRIMERGY BX920 S1 / PRIMERGY SX940 S1 HTML | Text |
2295 | 2.86 | CIFS | 72.5 | 6 | 438 GB | 1 | Gigabit Ethernet |
Fujitsu | PRIMERGY TX200 S5 HTML | Text |
6785 | 6.03 | CIFS | 97 | 16 | 1.75 TB | 1 | Gigabit Ethernet |
Fujitsu Siemens Computers | PRIMERGY NX650 HTML | Text |
3825 | 4.70 | CIFS | 4.5 | 12 | 1.2 TB | 2 | Gigabit Ethernet |
Fujitsu Siemens Computers | PRIMERGY NX650 HTML | Text |
3825 | 4.70 | CIFS | 4.5 | 12 | 1.2 TB | 2 | Gigabit Ethernet |
Fujitsu Siemens Computers | PRIMERGY RX300 S5 HTML | Text |
4857 | 4.63 | CIFS | 96.5 | 12 | 1.2 TB | 2 | Gigabit Ethernet |
Tested By | Product Name | Results | System Configuration | ||||||
Throughput | ORT | Protocol | Memory (GB) |
Disks | Exported Capacity |
Network Ports |
Network Type |
||
Fujitsu Siemens Computers | PRIMERGY TX300 S5 (with 3x6 disks RAID 50) HTML | Text |
9251 | 5.22 | CIFS | 97 | 20 | 1.6 TB | 2 | Gigabit Ethernet |
Huawei Symantec | Oceanspace N8500 Clustered NAS Storage System HTML | Text |
712664 | 1.81 | CIFS | 1344 | 1728 | 196608 GB | 8 | 10 Gigabit Ethernet |
Isilon Systems, LLC. | S200-6.9TB-200GB-48GB-10GBE - 140 Nodes HTML | Text |
1612778 | 2.34 | CIFS | 6790 | 3360 | 864.0 TB | 140 | 10GbE with Jumbo Frames |
Isilon Systems, LLC. | S200-6.9TB-200GB-48GB-10GBE - 56 Nodes HTML | Text |
605629 | 2.19 | CIFS | 2716 | 1344 | 344.5 TB | 56 | 10GbE with Jumbo Frames |
Isilon Systems, LLC. | S200-6.9TB-200GB-48GB-10GBE - 28 Nodes HTML | Text |
302985 | 2.17 | CIFS | 1358 | 672 | 172.3 TB | 28 | 10GbE with Jumbo Frames |
Isilon Systems, LLC. | S200-6.9TB-200GB-48GB-10GBE - 14 Nodes HTML | Text |
201628 | 3.18 | CIFS | 679 | 336 | 86.1 TB | 14 | 10GbE with Jumbo Frames |
Isilon Systems, LLC. | S200-6.9TB-200GB-48GB-10GBE - 7 Nodes HTML | Text |
110201 | 3.05 | CIFS | 339.5 | 168 | 43.1 TB | 7 | 10GbE with Jumbo Frames |
NSPLab(SM) Performed Benchmarking | SPECsfs2008 Reference Platform (CIFS) HTML | Text |
3088 | 3.44 | CIFS | 6 | 25 | 3.3 TB | 1 | Gigabit Ethernet |
NetApp, Inc. | FAS3140 (FCAL Disks) HTML | Text |
55476 | 1.84 | CIFS | 9 | 224 | 42.66 TB | 4 | Jumbo Frame Gigabit Ethernet |
NetApp, Inc. | FAS3140 (FCAL Disks with Flash Cache) HTML | Text |
55398 | 1.25 | CIFS | 521 | 56 | 10.34 TB | 4 | Jumbo Frame Gigabit Ethernet |
NetApp, Inc. | FAS3140 (SATA Disks with Flash Cache) HTML | Text |
53546 | 1.48 | CIFS | 521 | 96 | 55.95 TB | 4 | Jumbo Frame Gigabit Ethernet |
NetApp, Inc. | FAS3210 HTML | Text |
64292 | 1.50 | CIFS | 522 | 144 | 86.96 TB | 4 | Jumbo Frame 1 Gigabit Ethernet |
NetApp, Inc. | FAS8020 HTML | Text |
105050 | 1.42 | CIFS | 1080 | 144 | 56 TB | 6 | Jumbo frame 10GbE |
Tested By | Product Name | Results | System Configuration | ||||||
Throughput | ORT | Protocol | Memory (GB) |
Disks | Exported Capacity |
Network Ports |
Network Type |
||
Silicon Graphics, Inc. | SGI InfiniteStorage NEXIS 9000 HTML | Text |
22744 | 1.58 | CIFS | 212 | 242 | 23404 GB | 4 | InfiniBand |
Last update: Thursday, 24 July 2014, 11:40
[Back to SFS2008]