naa.600c0ff000112f29c3062f4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000112f29c3062f4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba1:C0:T5:L0
    Working Paths: vmhba1:C0:T5:L0

naa.600c0ff00010efce21e62e4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff00010efce21e62e4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}{TPG_id=1,TPG_state=ANO}}
    Path Selection Policy: VMW_PSP_RR
    Path Selection Policy Device Config: {policy=rr,iops=1000,bytes=10485760,useANO=0;lastPathIndex=0: NumIOsPending=0,numBytesPending=0}
    Working Paths: vmhba1:C0:T2:L2

naa.600c0ff000112a6486e02e4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000112a6486e02e4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba1:C0:T6:L0
    Working Paths: vmhba1:C0:T6:L0

naa.600c0ff000113a462962344e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000113a462962344e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba1:C0:T3:L0
    Working Paths: vmhba1:C0:T3:L0

naa.600c0ff000113aa20000000000000000
    Device Display Name: HP Fibre Channel Enclosure Svc Dev (naa.600c0ff000113aa20000000000000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba2:C0:T4:L0
    Working Paths: vmhba2:C0:T4:L0

naa.600c0ff000113a7f6864344e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000113a7f6864344e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}{TPG_id=1,TPG_state=ANO}}
    Path Selection Policy: VMW_PSP_RR
    Path Selection Policy Device Config: {policy=rr,iops=1000,bytes=10485760,useANO=0;lastPathIndex=0: NumIOsPending=0,numBytesPending=0}
    Working Paths: vmhba1:C0:T0:L2

naa.600c0ff000112a883962344e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000112a883962344e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba2:C0:T3:L1
    Working Paths: vmhba2:C0:T3:L1

naa.600c0ff00010f63a5864344e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff00010f63a5864344e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba2:C0:T0:L1
    Working Paths: vmhba2:C0:T0:L1

naa.600c0ff000113a7f4864344e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000113a7f4864344e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba1:C0:T0:L0
    Working Paths: vmhba1:C0:T0:L0

naa.600c0ff00010f63a0000000000000000
    Device Display Name: HP Fibre Channel Enclosure Svc Dev (naa.600c0ff00010f63a0000000000000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba2:C0:T0:L0
    Working Paths: vmhba2:C0:T0:L0

naa.600c0ff000113a2cd3062f4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000113a2cd3062f4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba2:C0:T5:L1
    Working Paths: vmhba2:C0:T5:L1

naa.600c0ff000113aa258202f4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000113aa258202f4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba2:C0:T4:L1
    Working Paths: vmhba2:C0:T4:L1

naa.600c0ff000112e2b69202f4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000112e2b69202f4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}{TPG_id=0,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_RR
    Path Selection Policy Device Config: {policy=rr,iops=1000,bytes=10485760,useANO=0;lastPathIndex=1: NumIOsPending=0,numBytesPending=0}
    Working Paths: vmhba1:C0:T4:L2

naa.600c0ff000113047f6e52e4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000113047f6e52e4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba2:C0:T2:L1
    Working Paths: vmhba2:C0:T2:L1

naa.600c0ff000113bcef4012f4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000113bcef4012f4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}{TPG_id=1,TPG_state=ANO}}
    Path Selection Policy: VMW_PSP_RR
    Path Selection Policy Device Config: {policy=rr,iops=1000,bytes=10485760,useANO=0;lastPathIndex=0: NumIOsPending=0,numBytesPending=0}
    Working Paths: vmhba1:C0:T1:L2

naa.600c0ff0001130470000000000000000
    Device Display Name: HP Fibre Channel Enclosure Svc Dev (naa.600c0ff0001130470000000000000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba2:C0:T2:L0
    Working Paths: vmhba2:C0:T2:L0

naa.600c0ff000113bb70000000000000000
    Device Display Name: HP Fibre Channel Enclosure Svc Dev (naa.600c0ff000113bb70000000000000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba2:C0:T1:L0
    Working Paths: vmhba2:C0:T1:L0

naa.600c0ff000112fdd99e02e4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000112fdd99e02e4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba2:C0:T6:L1
    Working Paths: vmhba2:C0:T6:L1

naa.600508b1001c080a6666d51bc7df78b5
    Device Display Name: HP Serial Attached SCSI Disk (naa.600508b1001c080a6666d51bc7df78b5)
    Storage Array Type: VMW_SATP_LOCAL
    Storage Array Type Device Config: SATP VMW_SATP_LOCAL does not support device configuration.
    Path Selection Policy: VMW_PSP_FIXED
    Path Selection Policy Device Config: {preferred=vmhba0:C0:T0:L0;current=vmhba0:C0:T0:L0}
    Working Paths: vmhba0:C0:T0:L0

naa.600c0ff000113a2c0000000000000000
    Device Display Name: HP Fibre Channel Enclosure Svc Dev (naa.600c0ff000113a2c0000000000000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba2:C0:T5:L0
    Working Paths: vmhba2:C0:T5:L0

naa.600c0ff000112e2b42202f4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000112e2b42202f4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba1:C0:T4:L0
    Working Paths: vmhba1:C0:T4:L0

naa.600c0ff000113bceb5012f4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000113bceb5012f4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba1:C0:T1:L0
    Working Paths: vmhba1:C0:T1:L0

naa.600c0ff000113a464862344e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000113a464862344e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}{TPG_id=1,TPG_state=ANO}}
    Path Selection Policy: VMW_PSP_RR
    Path Selection Policy Device Config: {policy=rr,iops=1000,bytes=10485760,useANO=0;lastPathIndex=0: NumIOsPending=0,numBytesPending=0}
    Working Paths: vmhba1:C0:T3:L2

naa.600c0ff000112a880000000000000000
    Device Display Name: HP Fibre Channel Enclosure Svc Dev (naa.600c0ff000112a880000000000000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba2:C0:T3:L0
    Working Paths: vmhba2:C0:T3:L0

naa.600c0ff000113bb7cd012f4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000113bb7cd012f4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba2:C0:T1:L1
    Working Paths: vmhba2:C0:T1:L1

naa.600c0ff000112fdd0000000000000000
    Device Display Name: HP Fibre Channel Enclosure Svc Dev (naa.600c0ff000112fdd0000000000000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba2:C0:T6:L0
    Working Paths: vmhba2:C0:T6:L0

naa.600c0ff000112f29e3062f4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000112f29e3062f4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}{TPG_id=1,TPG_state=ANO}}
    Path Selection Policy: VMW_PSP_RR
    Path Selection Policy Device Config: {policy=rr,iops=1000,bytes=10485760,useANO=0;lastPathIndex=0: NumIOsPending=0,numBytesPending=0}
    Working Paths: vmhba1:C0:T5:L2

naa.600c0ff000112a64b0e02e4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff000112a64b0e02e4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}{TPG_id=1,TPG_state=ANO}}
    Path Selection Policy: VMW_PSP_RR
    Path Selection Policy Device Config: {policy=rr,iops=1000,bytes=10485760,useANO=0;lastPathIndex=0: NumIOsPending=0,numBytesPending=0}
    Working Paths: vmhba1:C0:T6:L2

naa.600c0ff00010efcee5e52e4e01000000
    Device Display Name: HP Fibre Channel Disk (naa.600c0ff00010efcee5e52e4e01000000)
    Storage Array Type: VMW_SATP_ALUA
    Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}}
    Path Selection Policy: VMW_PSP_MRU
    Path Selection Policy Device Config: Current Path=vmhba1:C0:T2:L0
    Working Paths: vmhba1:C0:T2:L0

