Hewlett Packard Enterprise Apollo XL225n Gen10 Plus SPECpower_ssj2008 = 17,696 overall ssj_ops/watt
Test Sponsor: Hewlett Packard Enterprise SPEC License #: 3 Test Method: Multi Node
Tested By: Hewlett Packard Enterprise Test Location: Houston, TX, USA Test Date: Feb 22, 2021
Hardware Availability: Mar-2021 Software Availability: Jul-2020 Publication: Mar 15, 2021
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
Calibration 1 2,182 22.8
Calibration 2 2,264 22.8
Calibration 3 2,264 22.8
100% 2,260 22.8
90% 2,097 22.8
80% 1,928 22.8
70% 1,768 22.7
60% 1,605 22.7
50% 1,360 22.7
40% 1,161 22.8
30% 1,053 22.9
20% 940 22.9
10% 812 23.0
Active Idle 523 23.0
Graph of power and temperature
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa
Model: WT210
Serial Number: 91GB47169
Connectivity: GPIB vi NI GPIB-USB-HS
Input Connection: Default
Metrology Institute: NIST
Accredited by: TRANSCAT
Calibration Label: 5-FQ7PK-180-1
Date of Calibration: 17-Jun-2020
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.9.2-3976349f-20201208
Setup Description: SUT connected to Power Supply 1
Power Analyzer pwr2
Hardware Vendor: Yokogawa
Model: WT210
Serial Number: 91GB47167
Connectivity: GPIB vi NI GPIB-USB-HS
Input Connection: Default
Metrology Institute: NIST
Accredited by: TRANSCAT
Calibration Label: 5-FQ7PK-20-1
Date of Calibration: 15-Jun-2020
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.9.2-3976349f-20201208
Setup Description: SUT connected to Power Supply 2
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: 5.70.105.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 5 mm in front of SUT main intake
Notes
None
Power Details for Device pwr1
Target Load Voltage (V) Current (A) Avg Power Factor Avg Active Power (W) Power Measurement Uncertainty (%)
Avg Range Avg Range
Calibration 1 210 300.0 5.26 10.0 0.994 1,098 0.4%
Calibration 2 210 300.0 5.45 10.0 0.995 1,139 0.4%
Calibration 3 210 300.0 5.45 10.0 0.995 1,140 0.4%
100% 210 300.0 5.44 10.0 0.995 1,137 0.4%
90% 210 300.0 5.07 10.0 0.994 1,060 0.5%
80% 211 300.0 4.66 10.0 0.993 975 0.5%
70% 211 300.0 4.28 10.0 0.992 895 0.5%
60% 211 300.0 3.87 10.0 0.993 811 0.5%
50% 211 300.0 3.31 5.0 0.991 692 0.4%
40% 211 300.0 2.84 5.0 0.989 594 0.4%
30% 211 300.0 2.59 5.0 0.987 540 0.5%
20% 211 300.0 2.33 5.0 0.984 484 0.5%
10% 212 300.0 2.03 5.0 0.979 420 0.5%
Active Idle 212 300.0 1.37 2.0 0.949 275 0.4%
Power details for pwr1
Power Details for Device pwr2
Target Load Voltage (V) Current (A) Avg Power Factor Avg Active Power (W) Power Measurement Uncertainty (%)
Avg Range Avg Range
Calibration 1 210 300.0 5.20 10.0 0.993 1,084 0.5%
Calibration 2 210 300.0 5.39 10.0 0.993 1,125 0.4%
Calibration 3 210 300.0 5.39 10.0 0.993 1,125 0.4%
100% 210 300.0 5.38 10.0 0.993 1,123 0.4%
90% 210 300.0 4.97 10.0 0.992 1,038 0.5%
80% 210 300.0 4.57 10.0 0.991 953 0.5%
70% 211 300.0 4.18 10.0 0.992 873 0.5%
60% 211 300.0 3.80 10.0 0.992 794 0.6%
50% 211 300.0 3.20 5.0 0.990 668 0.4%
40% 211 300.0 2.72 5.0 0.987 567 0.4%
30% 211 300.0 2.47 5.0 0.984 513 0.5%
20% 211 300.0 2.20 5.0 0.980 456 0.5%
10% 212 300.0 1.90 5.0 0.975 393 0.6%
Active Idle 212 300.0 1.26 2.0 0.937 249 0.5%