Hewlett Packard Enterprise Synergy 480 Gen10 Compute Module | SPECpower_ssj2008 = 11,754 overall ssj_ops/watt | ||||
Test Sponsor: | Hewlett Packard Enterprise | SPEC License #: | 3 | Test Method: | Multi Node |
Tested By: | Hewlett Packard Enterprise | Test Location: | Houston, TX, USA | Test Date: | Mar 26, 2019 |
Hardware Availability: | Apr-2019 | Software Availability: | Mar-2019 | Publication: | May 8, 2019 |
System Source: | Single Supplier | System Designation: | Server | Power Provisioning: | Line-powered |
Target Load | Average Active Power (W) | Minimum Ambient Temperature (°C) |
---|---|---|
Calibration 1 | 4,514 | 23.8 |
Calibration 2 | 4,521 | 23.7 |
Calibration 3 | 4,532 | 23.6 |
100% | 4,519 | 23.6 |
90% | 3,973 | 23.1 |
80% | 3,373 | 22.8 |
70% | 2,936 | 22.7 |
60% | 2,552 | 22.5 |
50% | 2,224 | 22.4 |
40% | 1,977 | 22.4 |
30% | 1,767 | 22.4 |
20% | 1,561 | 22.3 |
10% | 1,339 | 22.2 |
Active Idle | 779 | 22.2 |
Power Analyzer pwr1 | |
---|---|
Hardware Vendor: | Yokogawa |
Model: | WT210 |
Serial Number: | 91GB53024 |
Connectivity: | GPIB vi NI GPIB-USB-HS |
Input Connection: | Default |
Metrology Institute: | NIST |
Accredited by: | TRANSCAT |
Calibration Label: | 5-EM5Y4-80-1 |
Date of Calibration: | 21-Jun-2018 |
PTDaemon Host System: | same as CCS |
PTDaemon Host OS: | same as CCS |
PTDaemon Version: | 1.8.1-260d064e-20161220 |
Setup Description: | SUT Power Supplies 1 and 4 |
Power Analyzer pwr2 | |
---|---|
Hardware Vendor: | Yokogawa |
Model: | WT210 |
Serial Number: | 91GB47168 |
Connectivity: | GPIB vi NI GPIB-USB-HS |
Input Connection: | Default |
Metrology Institute: | NIST |
Accredited by: | TRANSCAT |
Calibration Label: | 5-EM5Y4-60-1 |
Date of Calibration: | 21-Jun-2018 |
PTDaemon Host System: | same as CCS |
PTDaemon Host OS: | same as CCS |
PTDaemon Version: | 1.8.1-260d064e-20161220 |
Setup Description: | SUT Power Supplies 2 and 5 |
Power Analyzer pwr3 | |
---|---|
Hardware Vendor: | Yokogawa |
Model: | WT210 |
Serial Number: | 91GC21887 |
Connectivity: | GPIB vi NI GPIB-USB-HS |
Input Connection: | Default |
Metrology Institute: | NIST |
Accredited by: | TRANSCAT |
Calibration Label: | 5-EM5Y4-20-1 |
Date of Calibration: | 21-Jun-2018 |
PTDaemon Host System: | same as CCS |
PTDaemon Host OS: | same as CCS |
PTDaemon Version: | 1.8.1-260d064e-20161220 |
Setup Description: | SUT Power Supplies 3 and 6 |
Temperature Sensor temp1 | |
---|---|
Hardware Vendor: | Digi International Inc. |
Model: | Watchport/H |
Driver Version: | 5.70.105.0 |
Connectivity: | USB |
PTDaemon Host System: | same as CCS |
PTDaemon Host OS: | same as CCS |
Setup Description: | 5 mm in front of SUT main intake |
Target Load | Voltage (V) | Current (A) | Avg Power Factor | Avg Active Power (W) | Power Measurement Uncertainty (%) | ||
---|---|---|---|---|---|---|---|
Avg | Range | Avg | Range | ||||
Calibration 1 | 211 | 300.0 | 5.39 | 10.0 | 0.993 | 1,128 | 0.4% |
Calibration 2 | 211 | 300.0 | 5.41 | 10.0 | 0.993 | 1,131 | 0.4% |
Calibration 3 | 210 | 300.0 | 5.41 | 10.0 | 0.993 | 1,131 | 0.4% |
100% | 210 | 300.0 | 5.39 | 10.0 | 0.993 | 1,126 | 0.4% |
90% | 210 | 300.0 | 4.79 | 10.0 | 0.992 | 999 | 0.5% |
80% | 211 | 300.0 | 4.03 | 10.0 | 0.990 | 840 | 0.5% |
70% | 211 | 300.0 | 3.50 | 5.0 | 0.986 | 726 | 0.4% |
60% | 211 | 300.0 | 3.04 | 5.0 | 0.982 | 629 | 0.4% |
50% | 211 | 300.0 | 2.65 | 5.0 | 0.976 | 546 | 0.5% |
40% | 211 | 300.0 | 2.37 | 5.0 | 0.970 | 485 | 0.5% |
30% | 211 | 300.0 | 2.14 | 5.0 | 0.964 | 435 | 0.5% |
20% | 211 | 300.0 | 1.92 | 5.0 | 0.955 | 387 | 0.6% |
10% | 211 | 300.0 | 1.68 | 2.0 | 0.942 | 333 | 0.4% |
Active Idle | 211 | 300.0 | 1.10 | 2.0 | 0.835 | 193 | 0.6% |
Target Load | Voltage (V) | Current (A) | Avg Power Factor | Avg Active Power (W) | Power Measurement Uncertainty (%) | ||
---|---|---|---|---|---|---|---|
Avg | Range | Avg | Range | ||||
Calibration 1 | 213 | 300.0 | 5.07 | 10.0 | 0.996 | 1,076 | 0.4% |
Calibration 2 | 213 | 300.0 | 5.06 | 10.0 | 0.996 | 1,075 | 0.4% |
Calibration 3 | 213 | 300.0 | 5.09 | 10.0 | 0.996 | 1,079 | 0.4% |
100% | 213 | 300.0 | 5.07 | 10.0 | 0.996 | 1,076 | 0.4% |
90% | 213 | 300.0 | 4.37 | 10.0 | 0.994 | 926 | 0.5% |
80% | 213 | 300.0 | 3.78 | 10.0 | 0.993 | 800 | 0.5% |
70% | 213 | 300.0 | 3.32 | 5.0 | 0.992 | 702 | 0.4% |
60% | 213 | 300.0 | 2.93 | 5.0 | 0.988 | 618 | 0.4% |
50% | 214 | 300.0 | 2.57 | 5.0 | 0.985 | 540 | 0.5% |
40% | 214 | 300.0 | 2.27 | 5.0 | 0.981 | 476 | 0.5% |
30% | 214 | 300.0 | 2.00 | 5.0 | 0.975 | 417 | 0.6% |
20% | 214 | 300.0 | 1.73 | 5.0 | 0.968 | 358 | 0.6% |
10% | 214 | 300.0 | 1.45 | 2.0 | 0.954 | 296 | 0.4% |
Active Idle | 214 | 300.0 | 0.931 | 2.0 | 0.857 | 171 | 0.6% |
Target Load | Voltage (V) | Current (A) | Avg Power Factor | Avg Active Power (W) | Power Measurement Uncertainty (%) | ||
---|---|---|---|---|---|---|---|
Avg | Range | Avg | Range | ||||
Calibration 1 | 210 | 300.0 | 11.1 | 10.0 | 0.995 | 2,309 | 0.4% |
Calibration 2 | 209 | 300.0 | 11.1 | 10.0 | 0.995 | 2,316 | 0.4% |
Calibration 3 | 209 | 300.0 | 11.2 | 10.0 | 0.995 | 2,323 | 0.4% |
100% | 209 | 300.0 | 11.1 | 10.0 | 0.996 | 2,317 | 0.4% |
90% | 209 | 300.0 | 9.82 | 10.0 | 0.996 | 2,047 | 0.3% |
80% | 210 | 300.0 | 8.31 | 10.0 | 0.994 | 1,733 | 0.3% |
70% | 210 | 300.0 | 7.24 | 10.0 | 0.992 | 1,508 | 0.4% |
60% | 210 | 300.0 | 6.27 | 10.0 | 0.990 | 1,305 | 0.4% |
50% | 210 | 300.0 | 5.49 | 10.0 | 0.987 | 1,139 | 0.4% |
40% | 210 | 300.0 | 4.91 | 10.0 | 0.984 | 1,016 | 0.5% |
30% | 211 | 300.0 | 4.43 | 10.0 | 0.980 | 914 | 0.5% |
20% | 211 | 300.0 | 3.97 | 5.0 | 0.976 | 816 | 0.4% |
10% | 211 | 300.0 | 3.48 | 5.0 | 0.968 | 710 | 0.4% |
Active Idle | 211 | 300.0 | 2.17 | 5.0 | 0.908 | 415 | 0.6% |