| Huawei Technologies Co., Ltd BH622 V2 | SPECpower_ssj2008 = 4,806 overall ssj_ops/watt | ||||
| Test Sponsor: | Huawei Technologies Co., Ltd | SPEC License #: | 3175 | Test Method: | Multi Node |
| Tested By: | Huawei Technologies Co., Ltd | Test Location: | Shenzhen, Guangdong, China | Test Date: | Aug 21, 2012 |
| Hardware Availability: | Aug-2012 | Software Availability: | Dec-2011 | Publication: | Sep 5, 2012 |
| System Source: | Single Supplier | System Designation: | Server | Power Provisioning: | Line-powered |
| Target Load | Average Active Power (W) | Minimum Ambient Temperature (°C) |
|---|---|---|
| Calibration 1 | 989 | 22.9 |
| Calibration 2 | 1,001 | 22.8 |
| Calibration 3 | 1,003 | 22.8 |
| 100% | 1,003 | 22.7 |
| 90% | 885 | 22.7 |
| 80% | 725 | 22.6 |
| 70% | 625 | 22.6 |
| 60% | 548 | 22.6 |
| 50% | 478 | 22.6 |
| 40% | 439 | 22.5 |
| 30% | 404 | 22.5 |
| 20% | 366 | 22.4 |
| 10% | 323 | 22.4 |
| Active Idle | 238 | 22.4 |
| Power Analyzer pwr1 | |
|---|---|
| Hardware Vendor: | Yokogawa Meters and Instruments Corporation |
| Model: | WT210 |
| Serial Number: | 91K630156 |
| Connectivity: | RS-232 |
| Input Connection: | Default |
| Metrology Institute: | CNAS (China National Accreditation Service for Conformity Assessment) |
| Accredited by: | Calibration and Testing Center of CEPREI |
| Calibration Label: | 2GB12006186-0010 |
| Date of Calibration: | 30-Jul-2012 |
| PTDaemon Host System: | same as CCS |
| PTDaemon Host OS: | same as CCS |
| PTDaemon Version: | 1.4.1-1271fb18-20110728 |
| Setup Description: | none |
| Temperature Sensor temp1 | |
|---|---|
| Hardware Vendor: | Temperature@lert |
| Model: | TM-STD30 |
| Driver Version: | 3.1.0.0 |
| Connectivity: | USB |
| PTDaemon Host System: | same as CCS |
| PTDaemon Host OS: | same as CCS |
| Setup Description: | The Temperature@lert-TM-STD30 used a 2 meters USB extension cable to connect to the controller. The Temperature@lert probe was placed in front of the main airflow inlet of the SUT less than 50mm. |
| Target Load | Voltage (V) | Current (A) | Avg Power Factor | Avg Active Power (W) | Power Measurement Uncertainty (%) | ||
|---|---|---|---|---|---|---|---|
| Avg | Range | Avg | Range | ||||
| Calibration 1 | 221 | 300.0 | 4.55 | 5.0 | 0.983 | 989 | 0.3% |
| Calibration 2 | 221 | 300.0 | 4.60 | 5.0 | 0.983 | 1,001 | 0.3% |
| Calibration 3 | 221 | 300.0 | 4.61 | 5.0 | 0.984 | 1,003 | 0.3% |
| 100% | 221 | 300.0 | 4.61 | 5.0 | 0.984 | 1,003 | 0.3% |
| 90% | 222 | 300.0 | 4.08 | 5.0 | 0.981 | 885 | 0.3% |
| 80% | 223 | 300.0 | 3.33 | 5.0 | 0.978 | 725 | 0.4% |
| 70% | 224 | 300.0 | 2.87 | 5.0 | 0.972 | 625 | 0.4% |
| 60% | 225 | 300.0 | 2.52 | 5.0 | 0.968 | 548 | 0.4% |
| 50% | 225 | 300.0 | 2.21 | 5.0 | 0.962 | 478 | 0.5% |
| 40% | 226 | 300.0 | 2.03 | 5.0 | 0.957 | 439 | 0.5% |
| 30% | 226 | 300.0 | 1.87 | 5.0 | 0.952 | 404 | 0.5% |
| 20% | 227 | 300.0 | 1.71 | 5.0 | 0.946 | 366 | 0.6% |
| 10% | 227 | 300.0 | 1.52 | 5.0 | 0.937 | 323 | 0.6% |
| Active Idle | 228 | 300.0 | 1.17 | 2.0 | 0.898 | 238 | 0.5% |