Huawei Technologies Co., Ltd RH2485 V2 SPECpower_ssj2008 = Invalid overall ssj_ops/watt
Test Sponsor: Huawei Technologies Co., Ltd SPEC License #: 3175 Test Method: Single Node
Tested By: Huawei Technologies Co., Ltd Test Location: Shenzhen, Guangdong, China Test Date: Jun 11, 2012
Hardware Availability: Jun-2012 Software Availability: Dec-2011 Publication: Jun 28, 2012
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
INVALID: The voltage (231.12V) reported by power analyzer 'pwr1' rose above the maximum allowed voltage (231V) for the standard specified in config.line.standard.voltage (see Run Rules Section 2.8)
Benchmark Results Summary
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
Calibration 1 426 21.1
Calibration 2 429 21.1
Calibration 3 428 21.1
100% 428 21.1
90% 363 21.1
80% 316 21.1
70% 276 21.1
60% 243 21.1
50% 215 21.1
40% 199 21.1
30% 182 21.2
20% 164 21.4
10% 145 21.6
Active Idle 92.3 21.7
Graph of power and temperature
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Electric International Pte. Ltd.
Model: WT210
Serial Number: 91K630156
Connectivity: RS-232
Input Connection: Default
Metrology Institute: CNAS (China National Accreditation Service for Conformity Assessment)
Accredited by: Calibration and Testing Center of CEPREI
Calibration Label: B11004997-0007
Date of Calibration: 7-Jun-2012
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.4.1-1271fb18-20110728
Setup Description: none
Temperature Sensor temp1
Hardware Vendor: Temperature@lert
Model: TM-STD30
Driver Version: 3.1.0.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: The Temperature@lert-TM-STD30 used a 2 meters USB extension cable to connect to the controller. The Temperature@lert probe was placed in front of the main airflow inlet of the SUT less than 50mm.
Notes
SPECpower_ssj.props input.load_level.number_warehouses set to 64 due to a known inconsistency in processor reporting with this Java version.
Power Details for Device pwr1
Target Load Voltage (V) Current (A) Avg Power Factor Avg Active Power (W) Power Measurement Uncertainty (%)
Avg Range Avg Range
Calibration 1 226 300.0 1.91 2.0 0.989 426 0.6%
Calibration 2 227 300.0 1.91 2.0 0.989 429 0.6%
Calibration 3 228 300.0 1.90 2.0 0.989 428 0.6%
100% 227 300.0 1.90 2.0 0.989 428 0.6%
90% 228 300.0 1.62 2.0 0.985 363 0.6%
80% 227 300.0 1.42 2.0 0.982 316 0.6%
70% 228 300.0 1.24 2.0 0.976 276 0.7%
60% 228 300.0 1.09 1.0 0.981 243 0.6%
50% 228 300.0 0.956 1.0 0.985 215 0.6%
40% 229 300.0 0.884 1.0 0.983 199 0.6%
30% 229 300.0 0.809 1.0 0.980 182 0.6%
20% 230 300.0 0.734 1.0 0.974 164 0.6%
10% 230 300.0 0.655 1.0 0.966 145 0.7%
Active Idle 230 300.0 0.413 0.5 0.971 92.3 0.6%
Power details for pwr1