| Hewlett-Packard Company ProLiant ML110 G3 (Historical) | SPECpower_ssj2008 = 190 overall ssj_ops/watt | ||||
| Test Sponsor: | Intel Corp. | SPEC License #: | 3184 | Test Method: | Single Node |
| Tested By: | Principled Technologies, Inc. | Test Location: | Durham, NC, USA | Test Date: | Jan 21, 2011 |
| Hardware Availability: | Feb-2006 | Software Availability: | May-2009 | Publication: | Feb 23, 2011 |
| System Source: | Single Supplier | System Designation: | Server | Power Provisioning: | Line-powered |
| Target Load | Average Active Power (W) | Minimum Ambient Temperature (°C) |
|---|---|---|
| Calibration 1 | 171 | 24.1 |
| Calibration 2 | 171 | 24.3 |
| Calibration 3 | 170 | 24.7 |
| 100% | 169 | 24.6 |
| 90% | 164 | 24.7 |
| 80% | 157 | 24.8 |
| 70% | 153 | 24.7 |
| 60% | 147 | 24.8 |
| 50% | 137 | 24.8 |
| 40% | 131 | 24.6 |
| 30% | 125 | 24.6 |
| 20% | 118 | 24.3 |
| 10% | 112 | 24.3 |
| Active Idle | 105 | 24.1 |
| Power Analyzer pwr1 | |
|---|---|
| Hardware Vendor: | Yokogawa Electric International Pte. Ltd. |
| Model: | WT210 |
| Serial Number: | 91GB45373 |
| Connectivity: | RS-232 |
| Input Connection: | Default |
| Calibration Institute: | NIST |
| Accredited by: | Davis Calibration |
| Calibration Label: | 07-1673 |
| Date of Calibration: | 28-Jul-2010 |
| PTDaemon Host System: | same as CCS |
| PTDaemon Host OS: | same as CCS |
| PTDaemon Version: | 1.4.0-7071d9e7 |
| Setup Description: | SUT Power Supply |
| Temperature Sensor temp1 | |
|---|---|
| Hardware Vendor: | Digi International Inc. |
| Model: | Watchport/H |
| Driver Version: | 5.10.26.0 |
| Connectivity: | USB |
| PTDaemon Host System: | same as CCS |
| PTDaemon Host OS: | same as CCS |
| Setup Description: | 50 mm in front of SUT main air intake |
This benchmark result is intended to provide perspective on past power and/or performance using the historical hardware and/or software described on this result page.
The system as described on this result page was formerly generally available. At the time of this publication, it may not be shipping, and/or may not be supported, and/or may fail to meet other tests of General Availability described in the SPEC OSG Policy document, http://www.spec.org/osg/policy.html
This measured result may not be representative of the result that would be measured were this benchmark run with hardware and software available as of the publication date.
| Target Load | Voltage (V) | Current (A) | Avg Power Factor | Avg Active Power (W) | Power Measurement Uncertainty (%) | ||
|---|---|---|---|---|---|---|---|
| Avg | Range | Avg | Range | ||||
| Calibration 1 | 122 | 150.0 | 1.44 | 2.0 | 0.969 | 171 | 0.3% |
| Calibration 2 | 122 | 150.0 | 1.45 | 2.0 | 0.969 | 171 | 0.3% |
| Calibration 3 | 122 | 150.0 | 1.44 | 2.0 | 0.969 | 170 | 0.3% |
| 100% | 122 | 150.0 | 1.43 | 2.0 | 0.969 | 169 | 0.3% |
| 90% | 122 | 150.0 | 1.39 | 2.0 | 0.967 | 164 | 0.3% |
| 80% | 122 | 150.0 | 1.34 | 2.0 | 0.964 | 157 | 0.3% |
| 70% | 122 | 150.0 | 1.30 | 2.0 | 0.962 | 153 | 0.4% |
| 60% | 122 | 150.0 | 1.26 | 2.0 | 0.959 | 147 | 0.4% |
| 50% | 122 | 150.0 | 1.18 | 2.0 | 0.957 | 137 | 0.4% |
| 40% | 122 | 150.0 | 1.13 | 2.0 | 0.955 | 131 | 0.4% |
| 30% | 122 | 150.0 | 1.08 | 2.0 | 0.954 | 125 | 0.4% |
| 20% | 122 | 150.0 | 1.02 | 2.0 | 0.955 | 118 | 0.4% |
| 10% | 122 | 150.0 | 0.956 | 2.0 | 0.959 | 112 | 0.4% |
| Active Idle | 122 | 150.0 | 0.887 | 2.0 | 0.966 | 105 | 0.4% |