HPC2002 Result Copyright © 1999-2002 Standard Performance Evaluation Corporation |
|
Hewlett-Packard Company hp server rx2600 cluster (1500MHz Itanium2) |
|
| SPEC license # HPG2116 | Tested by: Hewlett-Packard Company | Test site: Richardson, Texas | Test date: Nov-2003 | Hardware Avail: Oct-2003 | Software Avail: Oct-2003 |
| Benchmark | Reference Time |
Runtime | Ratio | ![]() |
|---|---|---|---|---|
| 361.wrf_m | 86400 | 280 | 309 | |
| SPECenvM2002 | 309 | |||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||
| Notes / Tuning Information |
|---|
CPU(s) enabled: 48 (two per node, 24 nodes)
Other Hardware:
Computation Network:
Myrinet M3-E64 Switch Enclosure (Fiber)
Myrinet M3-SW16-8F 8-Port Line Card (8)
HP A6386 PCI HyperFabric2 Adapter
GigaBit on-board adapter for Administration and NFS
PCI GigaBit card for NFS traffic (GigE-TX adapter A6825A )
NFS file server:
rp5470 (PA-RISC) NFS File Server
4 PA8700 CPUs 750 MHz. 16 GB of memory
4 internal disks 73 GB Ultra2 SCSI
20 external disks 18 GB U160 SCSI striped with
LVM across 4 SCSI controllers
15 external disks 73 GB FibreChannel mirrored
with LVM across 2 FC controllers which
contain the NFS filesystems accessed by the benchmark.
These NFS filesystems are optimized for
security rather than performance.
File Server Network:
HP ProCurve 9308 64-port copper Gigabit Ethernet Switch
Built-in Gigabit Ethernet Adapters (one per node)
Peak Flags: MPI
mpif90 +DD64 +noppu +Ofast +Oinfo
mpicc +DD64 +Ofast -DNOUNDERSCORE -DSPEC_HPG_MPI2
OPTIMIZE =
ENV_SPEC_HPG_PARALLEL=MPI
CPPFLAGS = -I. -C -P
EXTRA_LIBS= -minshared -L${NETCDF}/lib/hpux64 -lnetcdf
NETCDF = /home/clpack/netcdf-3.5.0
FPORTABILITY= -I${NETCDF}/include
Alternate Source used for Peak:
None
Kernel Paramters (/stand/system):
maxdsiz 0x7b03a000
maxdsiz_64bit 0x4000000000
maxssiz 0x10000000
maxssiz_64bit 0x40000000
maxtsiz 1073741824
maxtsiz_64bit 4294967296
vps_pagesize 4
vps_ceiling 64
dbc_min_pct 3
dbc_max_pct 3
Peak User Environment:
use_submit_for_speed=1
submit = /home/f90pack/clust_mpirun $command
clust_mpirun:
mpirun -hmp -f appfile
appfile:
-h rx17-hf -np 2 -e MPI_HMP=ON -e MPI_WORKDIR=$cwd $command
...
-h rx40-hf -np 2 -e MPI_HMP=ON -e MPI_WORKDIR=$cwd $command
|
First published at SPEC.org on 26-Nov-2003
Generated on Thu Feb 5 16:18:59 2004 by SPEC HPC2002 HTML formatter v1.01